Pole with 480v 30 amp disconnect.
Mobile home meter pole installation.
5 1 2 from ground to center of meter mobile home poles and must be within 24 of eyebolt minimum of 12 heighth to weatherhead 200 amp.
Install on side of pole opposite service drop.
Fasten each strap with two galvanized 1 4 by 2 1 2 lag screws.
It is also suitable for service entrance equipment.
Some moving companies will only go so far to transport your mobile home and leave it to you to find a plumber electrician etc.
All meter sockets shall be mounted in a manner that allows meters to be inserted and withdrawn.
Hooking the home up to sewer lines and electric meters is not a simple diy project.
Trench depth shall be 30 inches minimum with or without gas service and greater if joint with a gas main.
Metering installations for mobile homes or mobile home parks.
Overhead service to mobile home.
With that said try finding a moving company that can will handle all aspects of installation.
Pole with meter base and 240v 200 amp disconnect.
When one of these mobile homes need a wiring overhaul it is best to upgrade to 200 amp service.
To do the rest of the work.
Street 36 min.
Overhead installations the metering pole must be a minimum of 17 ft class 5 pole set at least 4 ft deep so that it will be of sufficient height and stability to provide service drop clearances as shown on page 31.
Alternate location for pedestal.
Older mobile homes were manufactured to provide 100 amp electrical service.
Eaton s versatile mobile home panels have a user friendly design that allows for a faster cleaner installation.
Meter base mounted on exterior wall of house or mobile manufactured home.
Position pedestal so that electric meter is facing away from mobile home.
This does not require you to replace every foot of wire in the mobile home.
25 foot meter poles and fused disconnect poles.
Three metal conduit straps minimum one near top one mid way and one within a foot of the meter socket.
No joints above or within 2 feet of top of pole.
See below for our assembly guide for meter pole installation.
Pvc conduit to the home gray schedule 40 or.
Use 2 0 thw hotlegs with minimum 18 tails for connection tvec will spot all mobile home poles 1 neutral stranded copper meter base unbroken for connection galvanized steeples or wire holding.
The mhm200p is 200 amp unit and is designed with ample width to ensure plenty of room for wire bending and an easier installation.
Position pedestal so that electric meter is facing away from mobile home towards right of way.
Overhead service to.
25 foot pole no disconnect or meter base overhead service bare pole only 360 00.