The inverter without a built in brake transistor can be connected.
Mitsubishi inverter brake resistor.
The brake resistor may be mounted horizontally or vertically depending on a suitable surface location.
Otherwise a brake transistor failure or the like can overheat the brake resistor abnormally causing a fire.
The wire size used should be minimum 14 awg 2 1mm2.
When the brake resistor is mounted externally to the enclosure housing the inverter install a solid type 1 enclosure at least 8 times the volume size of the brake resistor that.
The high duty brake resistor cannot be used with a brake unit high power factor converter power return converter built in brake etc.
When the brake resistor is mounted externally to the enclosure housing the inverter install a solid type 1 enclosure at least 8 times the volume size of the brake resistor that incorporates mesh or perforated steel type ventilation.
240mm x 50mm x 21mm mounting.
Do not connect a resistor directly to the dc terminals p and n.
Installing the inverter directly on or near a combustible surface could lead to a fire.
Some drive models come come with a large brake transistor built in you can find their minimum resistance and max braking power in the drives with internal braking transistors table.
Returns regeneration energy to the power supply enabling continuous.
Returns regeneration energy to the power supply enabling continuous regeneration operation.
The inverter without a built in brake transistor can be connected.
Twist the leads of the high duty brake resistor when increas ing their length 2m or more.
If you are purchasing a braking unit from mitsubishi you can find your appropriate resistor by looking at the brake resistors for brake units table.
Install the high duty brake resistor fr abr as follows.
This instruction manual gives handling information and precautions for use of this equipment.
This could cause a fire and destroy the inverter.
Mitsubishi inverter option catalog 5 6 a700 1 2 3 regeneration unit option is necessary for regeneration.
The brake resistor may be mounted horizontally or vertically depending on a suitable surface location.
When connected to a suitable inverter drive this will reduce the stop time by absorbing energy returning from the load.
Refer to the instruction manual of the inverter.
The surface temperature of braking resistors can far exceed 100 c for brief periods.
Otherwise the brake resistor may excessively overheat due to damage of the brake transistor and such causing a fire.
Via 4 3mm diameter holes.
Mitsubishi external dynamic braking resistor 60 0 ohms x 120 watts 0 12kw.
A high power factor converter whose.
The brake unit the resistor unit and the dischaging resistor must be installed on a nonflammable wall without holes.
For use with fr d720s and fr e720s series inverters rated at 1 5kw or 2 2kw.
Thank you for choosing this mitsubishi inverter option unit.
Use the alarm signal of the brake unit to switch power off.